Duoclic II
Thermostat Combination
Tmax 250°C / Imax 16A / NC and NO combinable / short reaction time / orientation independent mounting / temperature resistant ceramic housing
Properly installed, the thermostat combination type 161 751 may be used for example in ovens, steam generators and washing machines and wherever two fixed temperatures need to be controlled or monitored.
Vaulted bimetal discs are used as temperature sensing elements. The discs are placed on the mounting plate in direct contact with the thermostat combination therefore reacting quickly to changes in temperature. Upon reaching the preset temperature, the bimetal discs operate and open (or close) the electrical circuit. Upon cooling, the discs snap back to their original position thereby closing (or opening) the circuit again.
The advantages of Duoclic II
Details
Technical Data
fixed Thermostat Combination
Switching cycles | Tmax | |||||
Type | Voltage | Current | VDE | cURus | ||
V Ni | A | °C | ||||
161751 | ||||||
001 - 0XY nc - nc | AC | 240 | 10 | 100.000 | 100.000 | 200 |
AC | 240 | 16 | 10.000 | 10.000 | 200 | |
301 - 3XY nc / nc | AC | 240 | 10 | 40.000 | 40.000 | 250 |
AC | 240 | 16 | 10.000 | 10.000 | 250 | |
AC | 240 | 23 | 1.000 | --- | 250 | |
AC | 240 | 26 | 300 | --- | 200 | |
AC | 400 | 7 | 10.000 | --- | 250 | |
AC | 400 | 16 | 300 | --- | 250 | |
401 - 4XY nc / nc | AC | 240 | 16 | 50.000 | 50.000 | 250 |
501 - 5XY nc / no | AC | 240 | 10 | 40.000 | 40.000 | 250 |
AC | 240 | 16 | 10.000 | 10.000 | 250 | |
AC | 240 | 16* | 10.000 | 10.000 | 250 | |
AC | 240 | 23 | 1.000 | --- | 250 | |
AC | 400 | 7 | 10.000 | --- | 250 | |
AC | 400 | 7* | 10.000 | --- | 250 | |
AC | 400 | 16 | 300 | --- | 250 | |
9A1 - 9XY nc / nc | AC | 240 | 1 | 50.000 | 50.000 | 250 |
AC | 400 | 1 | 10.000 | 10.000 | 250 | |
AC | 48 | 1 | 100.000 | 100.000 | 250 | |
901 - 99Y nc / no | AC | 240 | 16 | 10.000 | 10.000 | 250 |
AC | 240 | 1* | 50.000 | 50.000 | 250 | |
AC | 400 | 1* | 10.000 | 10.000 | 250 | |
AC | 48 | 1* | 100.000 | 100.000 | 250 |
nc normally closed
no normally open
General product features:
Switching temperature: | 60°C - Tmax |
Switching tolerance: | ± 5 K 60 - 180°C ± 7,5 K 180 - 250°C |
Differential: | 10 - 25K (standard) modification on request |
Rate of temperature rise: | > 1K/min |
Design: | according to DIN EN60730 protection class I |
Proof tracking indes PTI: | > 600V PTFE |
Applications
Properly installed, the thermostat combination type 161 751 may be used for example in ovens, steam generators and washing machines and wherever two fixed temperatures need to be controlled or monitored.
Structure and mode of operation
Vaulted bimetal discs are used as temperature sensing elements. The discs are placed on the mounting plate in direct contact with the thermostat combination therefore reacting quickly to changes in temperature. Upon reaching the preset temperature, the bimetal discs operate and open (or close) the electrical circuit. Upon cooling, the discs snap back to their original position thereby closing (or opening) the circuit again.
Advantages
- easy mounting
- both components mounted onto one base plate with homogenous heat transfer
- protected contact system, no cover cap necessary
- orientation independent switching behavior
- short reaction time, suitable for powerful + low-mass heating elements
- robust ceramic housing with separate switching chambers
- stable switching temperatures even under different current load
- high contact force and low contact resistance
- high dielectric strength even after many switching operations
- defined temperature drift over the service life
- consistent performance characteristics and product quality through fully automated production
Approbation
refer to approvals list which is available on request.
Applications
Downloads
List of all available downloads.
Download file | Version | Extension | Size | |
---|---|---|---|---|
Data sheet_161751
|
536 KB | Download |