digsy® fusion S-P
Modular mobile suitable safety controller
High performance safety controller for mobile applications. Up to 4 GB file system and 15 MB application memory. 8 CAN interfaces, 2 Ethernet ports and USB. Scalable from 48 to 192 multifunctional I/O’s, each configurable as safe or standard. CODESYS 3.5 SIL2 programmable.
The safety controller digsy® fusion S-P is focusing on high demand applications. With its powerful 400 MHz CPU & FPU it outperforms existing automation solutions and enables designers to realize extraordinary functionality.
Vast memories allow the storage of detailed logging data over a long period as well as extensive configuration data like load charts for entire machine series.
Due to its connectivity featuring 8 CAN busses, 2 Ethernet ports, USB and RS-232 it is able to gather all common machine data, store them and transmit them whenever needed. Common protocols from CANopen / CANopen-Safety / J1939 up to Ethernet OPC UA, Modbus TCP, FTP, UDP and TCP/IP are supported. Easy access via Webserver is available.
Details
Technical Data
Safety controller with PLd, CAT 2 & 3 acc. to EN ISO 13849
- 32-bit Processor, 200 MHz
- 32-bit Floating-Point-Unit
- RAM: 16 MB - thereof up to 4 MB for variables
- Flash: 35 MB - thereof up to 1,5 MB for the application program
- thereof up to 16 MB for the file system - FRAM: 32 kB - thereof 2x 8 kB for retain data
- 32-bit Processor, 400 MHz (Performance extension)
- RAM: 32 MB
- Flash: 32 MB - thereof up to 15 MB for the application program
- FRAM: 32 kB - for retain data
- CF-card: 1 GB – with file system for e.g. data logging
- 8x CAN-interfaces (CANopen, J1939, Layer-2)
- 2x Ethernet ports (OPC UA, Modbus TCP, FTP, UDP and TCP/IP) with switch
- 2x RS-232 interfaces, Modbus or free programmable
- 10x LED, 8x state, 2x free programmable
- USB (Host, V2.0)
- Webserver
- Real time clock
12 outputs, multifunctional:
PWM, incl. current regulation - safe
Digital - safe
8 x 2,5 A
4 x 4,0 A
6 out- / inputs, multifunctional:
Digital outputs 4,0 A - safe
Digital inputs, plus-switching
6 inputs, multifunctional:
Digital inputs, plus-switching - safe
Digital inputs, ground-switching
8 inputs, multifunctional:
Digital inputs, plus-switching - safe
Counter/pulse inputs - safe
16 inputs, multifunctional:
Digital inputs, plus-switching - safe
Analog inputs - safe
0...20 mA, 0...10 V, 0...32 V
2 Reference voltage outputs:
10 V, switchable
1 Sensor supply output:
VIM, max. 400 mA, switchable
1 Reference current output
50mA, switchable
- Operating voltage: 8...32V
- Operating temperature: -40°C...+80°C (-40°F…+176°F)
- Aluminum enclosure with Goretex filter, salt water resistant
- Shock- vibration- and rock fall proof
- EMC proof according to automotive standards
- Integrated load dump protection
- Environmental protection: IP6K9K / IP6K7
- Dimensions:
appr. 161,5 x 252 x 67mm (48 I/O's)
appr. 161,5 x 252 x 115 mm (96 / 144 I/O's)
appr. 161,5 x 252 x 162 mm (192 I/O's) - E1 certification
I/O-extensions
Safe I/O module (SIOM):
12 outputs, multifunctional:
PWM, incl. current regulation - safe
Digital - safe
8 x 2,5 A
4 x 4,0 A
6 out- / inputs, multifunctional:
Digital outputs 4,0 A - safe
Digital inputs, plus-switching
6 inputs, multifunctional:
Digital inputs, plus-switching - safe
Digital inputs, ground-switching
8 inputs, multifunctional:
Digital inputs, plus-switching - safe
Counter/pulse inputs - safe
16 inputs, multifunctional:
Digital inputs, plus-switching - safe
Analog inputs - safe
0...20 mA, 0...10 V, 0...32 V
2 Reference voltage outputs:
10 V, switchable
1 Sensor supply output:
VIM, max. 400 mA, switchable
1 Reference current output
50mA, switchable
Order number
digsy® fusion S-P / 1GB – 48 safe I/Os
4888.03.301
digsy® fusion S-P / 1GB – 96 safe I/Os
4888.03.302
digsy® fusion S-P / 1GB – 144 safe I/Os
4888.03.304
digsy® fusion S-P / 1GB – 192 safe I/Os
4888.03.305
digsy® fusion S-P / 4GB – 48 safe I/Os
4888.03.321
digsy® fusion S-P / 4GB – 96 safe I/Os
4888.03.322
digsy® fusion S-P / 4GB – 144 safe I/Os
4888.03.324
digsy® fusion S-P / 4GB – 192 safe I/Os
4888.03.325
Accessories
Connector set, 64 poles
4305.51.001
Connector with 3m cable, 64 wires
4306.20.001*
Measurement box, for trouble shooting
4805.05.001
Y-junction M12, for CANbus
4305.37.001*
Sealing screw for unused M12-sockets
4305.84.001*
CAN-terminator, M12 connector
4305.85.001*
CAN-cable, 2m, M12-connector, loose end
4308.32.041*
CAN-cable, 2m, M12-connector-socket
4308.32.043*
LAN-cable, 2m, M12-connector
4308.33.041*
RS-232 cable COM1, 2m, M12-connector-D-Sub9
4308.34.044*
RS-232 cable COM2, 2m, M12-connector-D-Sub9
4308.34.045*
USB-cable, 1m, M12-connector-USB-A
4308.36.041*
Cable-Kit, contains the with * marked articles
4306.51.010
Applications
The advantages of digsy® fusion S-P
Powerful and communicative
Downloads
List of all available downloads.
Brochures
Download file | Version | Extension | Size | |
---|---|---|---|---|
Brochure digsy® fusion S-P
|
627 KB | Download |
Manuals
Download file | Version | Extension | Size | |
---|---|---|---|---|
Safety Manual digsy® fusion S
|
V01.15.01 | 7 MB | Download | |
Manual GCM-P
|
V01.03.01 | 3 MB | Download | |
Programming guidelines
|
V05.00.00 | 410 KB | Download | |
Application notes
|
V01.00.00 | 2 MB | Download |
Certificate
Download file | Version | Extension | Size | |
---|---|---|---|---|
Declaration of conformity 2020-02
|
February 2020 | png | 2 MB | Download |
Certificate Z10 020099 0006 Rev. 1
|
September 2022 | 394 KB | Download | |
EC-Type Examination Certificate
|
December 2020 | 162 KB | Download | |
ECHA - REACH (4888.03.xx1)
|
V01.xx.xx | png | 28 KB | Download |
ECHA - REACH (4888.03.xx2)
|
V01.xx.xx | png | 35 KB | Download |
ECHA - REACH (4888.03.xx4)
|
V01.xx.xx | png | 34 KB | Download |
ECHA - REACH (4888.03.xx5)
|
V01.xx.xx | png | 36 KB | Download |
Software
Download file | Version | Extension | Size | |
---|---|---|---|---|
CODESYS V3.5.16.60
https://partner.intercontrol.de/owncloud/index.php/s/BemwxlfbnhX5AqD |
V3.5.16.60 | |||
CODESYS V3.5.11.0
https://partner.intercontrol.de/owncloud/index.php/s/ibVUKE18NO8Kxuv |
V3.5.11.0 | |||
SISTEMA Library
|
V01.02.00 | slb | 1 MB | Download |
Default application dfS-P
|
V1.0.0 | ic | 6 KB | Download |
Default application GCM-P
|
V01.00.00 | zip | 22 KB | Download |
Pinout configuration tool (XLSX)
|
V1.0.0 | zip | 83 KB | Download |
Bootloader Tool dfX
|
V05.01.00 | zip | 8 MB | Download |
Demoprojects
Download file | Version | Extension | Size | |
---|---|---|---|---|
Basic diagnoses
|
V1.0.0 | projectarchive | 875 KB | Download |
Retain data handling
|
V1.0.3 | projectarchive | 6 MB | Download |
Shared Memory
|
V1.0.0 | projectarchive | 2 MB | Download |
Shared Memory OPC-UA
|
V1.0.0 | projectarchive | 3 MB | Download |
Drawings
Download file | Version | Extension | Size | |
---|---|---|---|---|
Step file DfS-P (small)
|
V01.00.00 | zip | 2 MB | Download |
Step file DfS-P (medium)
|
V01.00.00 | zip | 2 MB | Download |
Step file DfS-P (large)
|
V01.00.00 | zip | 2 MB | Download |
Module cable dfX
|