digsy® fusion S
Modular mobile suitable safety controller
digsy® fusion S is a 2nd generation 32-bit safety controller. Due to its redundant architecture it reaches Performance Level d and Categorie 3 according to EN ISO 13849 and AgPL d according to ISO 25119 and EN 16590. It is free programble according to IEC-61131-3 with CODESYS 3.5 SIL2.
digsy® fusion S is a versatile applicable, modular safety controller. The basis is the safe CPU board with 48 I/O´s and the communication interfaces. This can be expanded by up to 4 I/O expansion modules with 48 I/O´s each, to a maximum of 240 safe, respectively standard I/O´s.
The option to perform 2 programs in parallel, in one controller, is supported. A distinction is made between a safe program and a standard program for comfort functions. It is ensured that the standard program works interference free and does not influence the safe program. Modifications on the standard program can be performed fast and without comprehensive safety analysis. Complex mathematical calculations can be executed on a redundand floating point unit, even in the safe context.
With an Ethernet and 4 CAN bus interfaces the digsy® fusion S has sufficient communication options, e.g. to sensors, controllers, displays and IoT gateways.
By a large, internal file system and an extra logging memory the digsy® fusion S offers the opportunity to hold configurations files directly on the device. Addionally it features a FRAM for safe, redundand retain data. The USB port can be used to expand the memory or for service- and update concepts in the field.
With CODESYS 3.5 SIL2 a powerful software development environment is available which supports especially the realization of safety functions. The safe program as well as a standard program are generated with the same tool.

Details
Technical Data
- PLd, Cat. 2/3, TÜV certified
- 32-bit Dual Core Processor, 200 MHz, Lock step mode
- 32-bit Floating-Point-Unit for safe Real-operations
- RAM: 16 MB - thereof up to 4 MB for variables
- Flash: 35 MB - thereof up to 2 MB for the standard program
- thereof up to 1,5 MB for the safe program
- thereof up to 16 MB for the file system - Serial Flash: 64 MB for data logging
- FRAM: 32 kB - thereof 2x 8 kB for safe retain data
- 4x CAN-interfaces (CANopen-Safety, CANopen, J1939, Layer-2)
- 1x Ethernet interface (TCP/IP, UDP, FTP)
- 1x USB (Host, V2.0)
- 2x RS-232 interfaces, 1 of them free programmable
- 10x LED, 7x status, 3x free programable
12 outputs, multifunctional:
PWM, incl. current regulation - safe
Digital - safe
8 x 2,5 A
4 x 4,0 A
6 out- / inputs, multifunctional:
Digital outputs 4,0 A - safe
Digital inputs, plus-switching
6 inputs, multifunctional:
Digital inputs, plus-switching - safe
Digital inputs, ground-switching
8 inputs, multifunctional:
Digital inputs, plus-switching - safe
Counter/pulse inputs - safe
16 inputs, multifunctional:
Digital inputs, plus-switching - safe
Analog inputs - safe
0...20 mA, 0...10 V, 0...32 V
2 Reference voltage outputs:
10 V, switchable
1 Sensor supply output:
VIM, max. 400 mA, switchable
1 Reference current output
50mA, switchable
- Operating voltage: 8...32V
- Operating temperature: -40°C...+80°C (-40°F…+176°F)
- Aluminum enclosure with Goretex filter, salt water resistant
- Shock- vibration- and rock fall proof
- EMC proof according to automotive standards
- Integrated load dump protection
- Environmental protection: IP6K9K / IP6K7
- Dimensions:
appr. 161,5 x 252 x 67mm (48/ 96 I/O's)
appr. 161,5 x 252 x 115 mm (144/ 192 I/O's)
appr. 161,5 x 252 x 162 mm (240 I/O's) - E1 certification
I/O-extensions
12 outputs, multifunctional:
PWM, incl. current regulation - safe
Digital - safe
8 x 2,5 A
4 x 4,0 A
6 out- / inputs, multifunctional:
Digital outputs 4,0 A - safe
Digital inputs, plus-switching
6 inputs, multifunctional:
Digital inputs, plus-switching - safe
Digital inputs, ground-switching
8 inputs, multifunctional:
Digital inputs, plus-switching - safe
Counter/pulse inputs - safe
16 inputs, multifunctional:
Digital inputs, plus-switching - safe
Analog inputs - safe
0...20 mA, 0...10 V, 0...32 V
2 Reference voltage outputs:
10 V, switchable
1 Sensor supply output:
VIM, max. 400 mA, switchable
1 Reference current output
50mA, switchable
General I/O module (GIOM):
12 outputs, multifunctional:
PWM, current controlled
Digital output:
8 x 2,5 A
4 x 4 A
6 out- / inputs, multifunctional:
Digital output 4,0 A
Digital input / high-active
6 inputs, multifunctional:
Digital input / high-active
Digital input / low-active
8 inputs, multifunctional:
Digital input / high-active
Counter- / pulse-input
16 inputs, multifunctional:
Digital input / high-active
Analog input: 0...20 mA, 0...10 V, 0...32 V
2 Reference voltage outputs:
10 V, switchable
1 Sensor supply output:
VIM, max. 400 mA, switchable
1 Reference current output
50mA, switchable
Accessories
digsy Fusion cable kit
4306.51.010
Connection and measurement box
4805.05.001
Connector-set, 64 poles
4305.51.001
Connector with 3 m cable, 64 poles
4306.20.001
Content of cable-kit
LAN-cabel M12 connector 2 m
4308.33.041
Lock screw M12
4305.84.001
Connector with 3 m cable, 64 poles
4306.20.001
CAN cable M12 connector-plug 3 m
4308.32.043
CAN cable M12 connector 2 m
4308.32.041
CAN Termination resistor M12
4305.85.001
Y-splitter M12
4305.37.001
RS232-cable fusion Com1 2m
4308.34.044
RS232-cable fusion Com2 2 m
4308.34.045
USB-cable M12 connector 1 m
4308.36.041
Applications
The advantages of digsy® fusion S
Interference free separation of safe and standard functions - Modular I/O concept.
Downloads
List of all available downloads.
Brochures
Download file | Version | Extension | Size | |
---|---|---|---|---|
Brochure digsy® fusion S
|
4 MB | Download |
Manuals
Download file | Version | Extension | Size | |
---|---|---|---|---|
Safety Manual digsy® fusion S
|
V01.15.01 | 5 MB | Download | |
Errats Sheet digsy® fusion S
|
V01.14.00 | 586 KB | Download | |
Math-Lib manual
|
V01.04.00 | 698 KB | Download | |
Util Safety Library Manual
|
V01.02.00 | 2 MB | Download | |
easy280 Safety Library manual
|
V01.03.00 | 2 MB | Download | |
easy280 Standard Library manual
|
V01.01.00 | 2 MB | Download | |
FUSIONx01 Library manual
|
V01.01.00 | 1 MB | Download | |
Application Note
|
V01.00.00 | 2 MB | Download | |
CODESYS Programming guideline
|
V05.00.00 | 410 KB | Download |
Certificate
Download file | Version | Extension | Size | |
---|---|---|---|---|
Certificate Z10 020099 0006 Rev. 2
|
July 2024 | png | 809 KB | Download |
EC-Type Examination Certificate 2024
|
July 2024 | png | 581 KB | Download |
ECHA - REACH (4888.02.x01)
|
V03.xx.xx | png | 19 KB | Download |
ECHA - REACH (4888.02.x02)
|
V03.xx.xx | png | 25 KB | Download |
ECHA - REACH (4888.02.x04)
|
V03.xx.xx | png | 25 KB | Download |
ECHA - REACH (4888.02.x05)
|
V03.xx.xx | png | 26 KB | Download |
ECHA - REACH (4888.02.x07)
|
V03.xx.xx | png | 25 KB | Download |
Firmware
Download file | Version | Extension | Size | |
---|---|---|---|---|
CODESYS configuration file (TXT)
|
V01.00.00 | txt | 494 B | Download |
Software
Download file | Version | Extension | Size | |
---|---|---|---|---|
digsy® fusion S package V3.5.11.5
|
V3.5.11.5 | package | 12 MB | Download |
digsy® fusion S package V3.5.11.4
|
V3.5.11.4 | package | 12 MB | Download |
digsy® fusion S package V3.5.11.0
|
V3.5.11.0 | package | 5 MB | Download |
SIL2 PlugIn CDS V3.5.11.1
|
V3.5.11.1 | package | 7 MB | Download |
CODESYS V3.5.11.x
https://partner.intercontrol.de/owncloud/index.php/s/ibVUKE18NO8Kxuv |
V3.5.11.x | |||
digsy® fusion S package V3.5.5.4
|
V3.5.5.4 | package | 2 MB | Download |
digsy® fusion S package V3.5.5.3
|
V3.5.5.3 | package | 566 KB | Download |
digsy® fusion S package V3.5.5.2
|
V3.5.5.2 | package | 545 KB | Download |
SIL2 PlugIn CDS V3.5.5
|
V3.5.5 | package | 5 MB | Download |
CODESYS V3.5.5.0
https://partner.intercontrol.de/owncloud/index.php/s/KAFzfrlBMVjnNe7 |
V3.5.5 | |||
SISTEMA Library
|
V01.02.00 | slb | 1 MB | Download |
Pinout configuration tool (XLSX)
|
V1.0.0 | zip | 83 KB | Download |
CODESYS configuration file (*.bin.ic)
|
V01.00.00 | ic | 750 B | Download |
Default application dfS T1 SAFE
|
V01.02.00 | ic | 6 KB | Download |
Default application dfS T1 STD
|
V01.02.00 | ic | 6 KB | Download |
Default application dfS T2 SAFE
|
V01.02.00 | ic | 6 KB | Download |
Default application dfS T2 STD
|
V01.02.00 | ic | 6 KB | Download |
Default application dfS T3 SAFE
|
V01.02.00 | ic | 6 KB | Download |
Bootloader Tool dfX
|
V05.01.00 | zip | 8 MB | Download |
Demoprojects
Download file | Version | Extension | Size | |
---|---|---|---|---|
SAFE2SAFE Communication dfS T1
|
V01.01.00 | projectarchive | 12 MB | Download |
Sensorconnection dfS T2
|
V02.00.00 | projectarchive | 11 MB | Download |
UtilSafety SHM Retaindata dfS T2
|
V01.02.00 | projectarchive | 5 MB | Download |
Drawings
Download file | Version | Extension | Size | |
---|---|---|---|---|
Step file DfS (small)
|
V01.00.00 | zip | 2 MB | Download |
Step file DfS (medium)
|
V01.00.00 | zip | 2 MB | Download |
Step file DfS (large)
|
V01.00.00 | zip | 2 MB | Download |
Module cable dfX
|
V1.0.0 | 27 KB | Download |
History
Download file | Version | Extension | Size | |
---|---|---|---|---|
Modification list
|
V01.03.00 | 64 KB | Download | |
Modification list (old)
|
V01.01.00 | 31 KB | Download | |
Modification list dfS T1
|
V1.2.0 | 15 KB | Download | |
Modification list dfS T2
|
V1.2.0 | 15 KB | Download | |
Modification list dfS T3
|
V1.2.0 | 16 KB | Download | |
Modification list 4888.02.001
|
V1.13.1 | 64 KB | Download | |
Modification list 4888.02.002
|
V1.13.1 | 73 KB | Download | |
Modification list 4888.02.004
|
V1.13.1 | 78 KB | Download | |
Modification list 4888.02.101
|
V1.13.1 | 65 KB | Download | |
Modification list 4888.02.102
|
V1.13.1 | 76 KB | Download | |
Modification list 4888.02.104
|
V1.13.1 | 68 KB | Download | |
Modification list 4888.02.201
|
V1.7.1 | 56 KB | Download | |
Modification list 4888.02.202
|
V1.7.1 | 69 KB | Download | |
Modification list 4888.02.204
|
V1.7.1 | 69 KB | Download |