Article Number: 155631

TL+TL+TL Combination Minimelt Plus

Thermal Link/Thermal Link/Thermal Link-Combination

T 206°C / 229°C / 260°C / 298°C / 318°C / Imax13,5A / short reaction time / orientation independent mounting / temperature resistant ceramic housing / standard terminals

Properly installed, the thermal link type 155 631 may be used for example in coffeemakers, irons, fryers etc, and wherever a fi xed temperature may not be exceeded.

The thermal link has a melt solder insert in the mounting plate which is in direct thermal contact with the surface that is to be monitored. When the preset temperature is reached, the solder melts causing a pin to move which results in the electrical contacts opening. Resetting is not possible. 

Advantages Technical data Applications Downloads Callback
TL+TL+TL Combination Minimelt Plus

The advantages of TL+TL+TL Combination Minimelt Plus

  • easy mounting

    quick + safe + economically

  • short response time

    ideally suited for powerful heating elements

  • three components on one base plate

    space saving + easy mounting + homogeneous heat transfer

  • high continuous operating and limit temperatures

    more security for your applications

  • proven product quality

    consistent performance characteristics through automatic production

Details

fixed Thermal Link


The thermal link ’Minimelt Plus’ Type 155 631 is approved according to DIN VDE 0821 EN 60691 and is suitable for:

Ambient conditions: Temperature fuse for use under usual atmospheric conditions
Circuit conditions: Termal fuse for use in ohmic circuits.
Comparative tracking index: CTI > 250V

 

Characteristic values

VDE

Nominal current Ir 13,5 A
Cut-off current  Ib 20,3 A
Short-term overload current Ip 203 A
Nominal voltage  Ur 230 V

 

Special information
The thermal link should neither be coated or potted nor be used in impregnated windings. The thermal link is a non repairable part. In case of replacement an equivalent thermal link with same type number and  rated functional temperature Tf  should be used, mounted in exactly the same way. Th does not relate to the ambient temperature only but to the temperature measured at the mounting plate close to the  thermal element.

 

Characteristic temperatures
Tf ... Nominal temperature
Th ... Continuous operating temperature in  accordance with DIN EN 60691 (measured at  base plate near the solder insert) 
Tm ... Max. limit temperature

 

  VDE  
Tf (°C) Th (°C) Tm (°C)
206°C                170°C                500°C               
229°C 200°C 500°C
260°C 230°C 500°C
298°C 260°C 500°C
318°C 280°C 500°C

 

 

 

 

 

 

 

Tolerance for Tf  acc. to VDE 0821 / EN 60691 -10K

Properly installed, the thermal link type 155 631 may be used for example in coffeemakers, irons, fryers etc, and wherever a fi xed temperature may not be exceeded.

 

 

The thermal link has a melt solder insert in the mounting plate which is in direct thermal contact with the surface that is to be monitored. When the preset temperature is reached, the solder melts causing a pin to move which results in the electrical contacts opening. Resetting is not possible. 

  • current supply up to 13,5 A
  • three components mounted onto one base plate with homogenous heat transfer
  • large variance in different, discreet fuse temperatures from Tf 206°C up to 318°C
  • TH 100 approved
  • quick heat transfer and reaction time
  • consitent response time for different installation positions
  • high contact force and low contact resistance
  • simple, quick and safe installation with standard flange
  • plug-in and welded connections for a secure connection technology
  • high continuous operating temperature Th
  • high maximum limit temperature Tm = 500°C
  • consistent performance characteristics and product quality through fully automated production

The Approbation List will be provided upon request.

Applications

  • Major Appliances © AdobeStock

    Major Appliances

    Dishwasher, oven, professional cooking systems, washer

  • Industrial applications © iStock

    Industrial applications

    Switch cabinet heating, switch cabinet cooling, industrial heating

Downloads

List of all available downloads.

Download file Version Extension Size
Data sheet_155631
pdf 193 KB Download

Product inquiry Controls

Please fill in form. We will contact you soon.