Smarty Plus Limiter
Thermal Cut-out
Tmax 250°C / Imax 10A / short reaction time / orientation independent mounting / temperature resistant ceramic housing / standard terminals
Properly installed, the thermal limiter type 162 471 may be used for example in hot water boilers, coffee-machines with insulated jug and wherever the heating up of an electrical appliance needs to be interrupted permanently at a preset temperature.
A vaulted bimetal disc is used as the temperature sensing element. The disc is placed in direct contact with the mounting plate therefore reacting quickly to changes in temperature. Upon reaching the preset temperature the bimetal disc operates and opens the electrical circuit. After cooling process a steel disc avoids an automatic reset. The limiter has to be reset manually by pressing the reset tab. The limiter is available with an extra switch-off tab for interruption of the heating process.
The advantages of Smarty Plus Limiter
Details
Technical Data
fixed bimetal temperature controller
Nominal current: | AC 10 A 230 V NI 10.000 cycles AC 16 A 400 V NI 200 cycles |
Maximum temperature: | T 250 °C |
Switch-off temperatur: | max. 250 ºC |
Switch-off tolerance: | ± 7,5 K (standard) ± 5 K (for an additional charge) |
Rate of temperature rise: | > 1 K/min |
Design: | according to DIN EN 60730 protection class I |
Comparative tracking index: | PTI 250 |
Mark of conformity: | refer to approval list which is available on request |
Applications
Properly installed, the thermal limiter type 162 471 may be used for example in hot water boilers, coffee-machines with insulated jug and wherever the heating up of an electrical appliance needs to be interrupted permanently at a preset temperature.
Structure and mode of operation
A vaulted bimetal disc is used as the temperature sensing element. The disc is placed in direct contact with the mounting plate therefore reacting quickly to changes in temperature. Upon reaching the preset temperature the bimetal disc operates and opens the electrical circuit. After cooling process a steel disc avoids an automatic reset. The limiter has to be reset manually by pressing the reset tab. The limiter is available with an extra switch-off tab for interruption of the heating process.
Advantages
- manually switchable on/off
- easy mounting
- fast response
- Orientation independent mounting
- various connection and mounting options
Approbation
The Approbation List will be provided upon request.