Article Number: 162001

Discostat Limiter

Thermal Cut-out manual reset

Tmax 150°C / Imax 16A / switches 3 phases simultaneously / orientation independent

Available on request.

Properly installed, the temperature limiter type 162 001 may be used to control electrical devices with three-phase contact for example in hot water appliances and thermal heaters. 

A vaulted bimetal disc is used as temperature sensing element. The disc is placed in direct contact with the mounting plate therefore reacting quickly to changes in temperature. Upon reaching the preset temperature the bimetal disc operates and opens the electrical circuit. The limiter has to be reset manually by pressing the reset tab.

Advantages Technical data Applications Downloads Callback
Discostat Limiter

The advantages of Discostat Limiter

  • simultaneous switching of all 3 phases

    reliable + high-performing + reliable over the entire life cycle

  • fast response

    minimizes unwanted temperature overshoot when switching off

  • position independent

    unlimited performance + response time in all installation positions

  • high life span

    high-performing + reliable over the entire life cycle

  • various connection options

    flexible + variable

Details

fixed bimetal temperature controller


 

 

         Voltage

 

      Current

 

    Switching cycles

           Tmax, 

 Operating value

            Tmax,

    switching unit

              V Ni             A                  °C                 °C
AC 3x              230            10               1.000               160                160
AC 3x              230            16               1.000               150                150
AC 3x              400            10               1.000               160                160

 

General product features:

Automatic swich back: < -20 °C
Switching temperature: 60°C - Tmax
Switching tolerance: ± 7,5 K                 60 - 160°C
Differential: 10 - 25K
Rate of temperature rise:                      > 1 K/min
Design: according to DIN EN60730 protection class I
Proof tracking index PTI: > 175 V
Mark of conformity: VDE

Properly installed, the temperature limiter type 162 001 may be used to control electrical devices with three-phase contact for example in hot water appliances and thermal heaters. 

 

A vaulted bimetal disc is used as temperature sensing element. The disc is placed in direct contact with the mounting plate therefore reacting quickly to changes in temperature. Upon reaching the preset temperature the bimetal disc operates and opens the electrical circuit. The limiter has to be reset manually by pressing the reset tab.

  • Simultaneous switching of all 3 phases
  • Fast response behavior, position independent
  • Various connection options
  • Long service life

The Approbation List will be provided upon request.

Applications

  • Building heating / space heating © AdobeStock

    Building heating / space heating

    Heat pump, night storage heater, oil radiator, fan heater, frost monitor

Downloads

List of all available downloads.

Download file Version Extension Size
Data sheet_162001
pdf 102 KB Download

Product inquiry Controls