digsy® fusion G-P

Modular mobile suitable controller

High performance controller for mobile applications. 15 MB application memory, up to 4 GB filesystem, 8 CAN interfaces, 2 Ethernet ports and USB. Scalable from 48 to 192 multifunctional I/O’s. CODESYS 3.5 programmable.

The digsy® fusion G-P is focusing on high demand applications. With its 400 MHz CPU and FPU it allows the software engineer to realize complex functionaltities.   

The large memory allows extensiv data logging for a long periode of time as well as simultaneous storage of configuration data for entire machine series. 

8 CAN busses (CANopen, J1939, Layer 2), 2 Ethernet ports (OPC UA, FTP, UDP, TCP-IP), USB and RS232 allows the acquisition and transmission of typical machine data. An integrated web server allows an easy remote access.

Technical data Applications Advantages Downloads Callback
digsy® fusion G-P

Details

  • 32-bit Processor, 200 MHz
    • 32-bit Floating-Point-Unit
    • RAM: 16 MB - thereof up to 4 MB for variables
    • Flash: 19 MB - thereof up to 1,7 MB for the application program
                                     - thereof up to 15 MB for the file system
    • FRAM: 32 kB - thereof 2x 8 kB for retain data
       
  • 32-bit Processor, 400 MHz (Performance extension)
    • RAM: 32 MB
    • Flash: 32 MB - thereof up to 15 MB for the application program
    • FRAM: 32 kB - for retain data
    • CF-card: 1 GB – with file system for e.g. data logging
       
  • 8x CAN-interfaces (CANopen, J1939, Layer-2)
  • 2x Ethernet ports (TCP/IP, UDP, FTP, OPC-UA) with switch 
  • 2x RS-232 interfaces, Modbus or free programmable
  • 10x LED, 8x state, 2x free programmable
  • USB (Host, V2.0)
  • Webserver
  • Real time clock

12 to 60 Outputs multifunctional:          
PWM, current controlled
Digital output:
8-32 x 2,5 A
4-16 x 4,0 A

6 to 30 Out-/inputs multifunctional:       
Digital output 6x 4,0 A
Digital input/high-active

6 to 30 Inputs multifunctional:  
Digital input/high-active
Digital input/low-active

8 to 40 Inputs multifunctional:  
Digital input/high-active
Counter/puls-input

16 to 80 Inputs multifunctional: 
Digital input/high-active
Analog input: 0…20 mA, 0…10 V, 0…32 V

2 to 10 Reference voltage outputs:
5 V/ 10 V, switchable

1 to 5 Sensore supply output:
VIM, max. 400 mA, switchable

1 to 5 Reference current output
50mA, switchable

  • Operating voltage: 8...32V
  • Operating temperature: -40°C...+80°C (-40°F…+176°F)
  • Aluminum enclosure with Goretex filter, salt water resistant
  • Shock- vibration- and rock fall proof
  • EMC proof according to automotive standards
  • Integrated load dump protection
  • Environmental protection: IP6K9K / IP6K7
  • Dimensions:
    appr. 161,5 x 252 x 67mm (48 I/O's)
    appr. 161,5 x 252 x 115 mm (96 / 144 I/O's)
    appr. 161,5 x 252 x 162 mm (192 / 240 I/O's)
  • E1 certification

digsy® fusion G-P –   48 I/Os                           
4888.53.001 

digsy® fusion G-P –   96 I/Os                           
4888.53.002 

digsy® fusion G-P – 144 I/Os                           
4888.53.003 

digsy® fusion G-P – 192 I/Os                           
4888.53.004

digsy® fusion G-P – 240 I/Os                           
4888.53.005

digsy® fusion G-P –   48 I/Os                           
4888.53.001 

digsy® fusion G-P –   96 I/Os                           
4888.53.002 

digsy® fusion G-P – 144 I/Os                           
4888.53.003 

digsy® fusion G–P – 192 I/Os                           
4888.53.004

digsy® fusion G–P – 240 I/Os                           
4888.53.005

Connector set, 64 poles                
4305.51.001  

Connector with 3m cable, 64 wires 
4306.20.001*

  

Measurement box, for trouble shooting          
4805.05.001

 

Y-junction M12, for CANbus          
4305.37.001* 

Sealing screw for unused M12-sockets          
4305.84.001* 

CAN-terminator, M12-connector     
4305.85.001* 

CAN-cable, 2m, M12-connector, loose end     
4308.32.041* 

CAN-cable, 2m, M12-connector-socket          
4308.32.043*  

LAN-cable, 2m, M12-connector      
4308.33.041* 

RS-232 cable COM1, 2m, M12-connector-D-Sub9       
4308.34.044* 

RS-232 cable COM2, 2m, M12-connector-D-Sub9       
4308.34.045* 

USB-cable, 1m, M12-connector-USB-A          
4308.36.041* 

 

Cable-Kit, contains the with * marked articles  
4306.51.010

Applications

The advantages of digsy® fusion G-P

Powerful and communicative

  • Powerful

    By a 400 MHz CPU with integrated FPU sufficient performance is available to realize even ambitious applications. Thus very short cycle times can be achieved.

  • Kommunikativ

    Sehr viele Schnittstellen in Verbindung mit viel Speicher sorgt für umfangreiche- und schnelle Kommunikationsmöglichkeiten. Durch einen integrierten OPC-UA Server kann die digsy fusion G-P in jegliche IoT-Umgebung integriert werden.

Downloads

List of all available downloads.

Brochures

Download file Version Extension Size
Brochure digsy® fusion G-P
pdf 262 KB Download

Manuals

Download file Version Extension Size
Manual dfG-P V030100
  • Manual for digsy fusion G-P
    (valid from 4888.53.XXX V02.03.XX)
V03.01.00 pdf 5 MB Download
Manual dfG-P V020600
  • Manual for digsy fusion G-P
    (valid up to 4888.53.XXX V01.XX.XX)
V02.06.00 pdf 5 MB Download
Errata sheet dfG-P V020600
  • Errata sheet for digsy fusion G-P
    (valid up to 4888.53.XXX V01.00.XX)
V02.06.00 pdf 272 KB Download
Manual GCM-P V010301
  • Manual for GCM-P V010301
V01.03.01 pdf 3 MB Download
Manual MTC-GB
  • Manual for library functions of MTC-GB
    (Library functions correspond also to GCM-P)
V01.02.00 pdf 767 KB Download

Certificate

Download file Version Extension Size
ECHA - REACH (4888.53.xx2)
  • ECHA - REACH data for 4888.53.xx2
V02.xx.xx csv 952 B Download
ECHA - REACH (4888.53.xx3)
  • ECHA - REACH data for 4888.53.xx3
V02.xx.xx csv 953 B Download
ECHA - REACH (4888.53.xx4)
  • ECHA - REACH data for 4888.53.xx4
V02.xx.xx csv 1 KB Download
ECHA - REACH (4888.53.xx5)
  • ECHA - REACH data for 4888.53.xx5
V02.xx.xx csv 1 KB Download
ECHA - REACH (4888.53.001)
  • ECHA - REACH data for 4888.53.001
V01.xx.xx csv 790 B Download
ECHA - REACH (4888.53.002)
  • ECHA - REACH data for 4888.53.002
01.xx.xx csv 953 B Download
Certificate
  • Certificate for dfG and DfG-P
January 2023 pdf 770 KB Download
ECHA - REACH (4888.53.xx1)
  • ECHA - REACH data for 4888.53.xx1
V02.xx.xx csv 791 B Download
ECHA - REACH (4888.53.x03)
  • ECHA - REACH data for 4888.53.x03
V01.xx.xx csv 953 B Download
ECHA - REACH (4888.53.x04)
  • ECHA - REACH data for 4888.53.x04
V01.xx.xx csv 1 KB Download

Firmware

Download file Version Extension Size
FW Update digsy fusion G-P
  • Beschreibung zum FW Update der digsy fusion G-P
V01.00.00 pdf 626 KB Download
ZIP-File 4888.53.00X
  • ZIP-Datei für das FW Update dfG-P (4888.53.00X)
V01.07.01 zip 2 MB Download

Software

Download file Version Extension Size
dfG-P Package V3.5.17.2
  • dfG-P Package for CODESYS V3.5.17 with device description, libraries, etc.
V3.5.17.2 package 13 MB Download
CODESYS V3.5.17.2

https://partner.intercontrol.de/owncloud/index.php/s/Y3z4wbizEeavuWi

V3.5.17.2
Pinout configuration tool (XLSX)
  • Pinout configuration tool for IO configuration of digsyfusion G-P (XLSX file)
V1.0.0 zip 80 KB Download
ZIP-Datei Default-APPs 4888.53.001 V02.xx
  • ZIP-Datei mit Default-App und GCM-P App für dfG-P ab V02.XX.XX mit 48 IOs
    - ".bin.ic" für GCM-Eth-SL V02.03.XX
    - ".projectarchive" für GCM-P V02.03.XX
V02.03.10 zip 2 MB Download
ZIP-Datei Default-APPs 4888.53.002 V02.xx
  • ZIP-Datei mit Default-App und GCM-P App für dfG-P ab V02.XX.XX mit 96 IOs
    - ".bin.ic" für GCM-Eth-SL V02.03.XX
    - ".projectarchive" für GCM-P V02.03.XX
V02.03.10 zip 2 MB Download
ZIP-Datei Default-APPs 4888.53.003 V02.xx
  • ZIP-Datei mit Default-App und GCM-P App für dfG-P ab V02.XX.XX mit 144 IOs
    - ".bin.ic" für GCM-Eth-SL V02.03.XX
    - ".projectarchive" für GCM-P V02.03.XX
V02.03.10 zip 2 MB Download
ZIP-Datei Default-APPs 4888.53.004 V02.xx
  • ZIP-Datei mit Default-App und GCM-P App für dfG-P ab V02.XX.XX mit 192 IOs
    - ".bin.ic" für GCM-Eth-SL V02.03.XX
    - ".projectarchive" für GCM-P V02.03.XX
V02.03.10 zip 2 MB Download
ZIP-Datei Default-APPs 4888.53.005 V02.xx
  • ZIP-Datei mit Default-App und GCM-P App für dfG-P ab V02.XX.XX mit 240 IOs
    - ".bin.ic" für GCM-Eth-SL V02.03.XX
    - ".projectarchive" für GCM-P V02.03.XX
V02.03.10 zip 2 MB Download
ZIP-Datei Default-APPs 4888.53.001 V01.xx
  • ZIP-Datei mit Default-App und GCM-P App für dfG-P bis V01.XX.XX mit 48 IOs
    - ".bin.ic" für GCM-Eth-SL V01.02.XX
    - ".projectarchive" für GCM-P V01.02.XX
V01.02.00 zip 2 MB Download
ZIP-Datei Default-APPs 4888.53.002 V01.xx
  • ZIP-Datei mit Default-App und GCM-P App für dfG-P bis V01.XX.XX mit 96 IOs
    - ".bin.ic" für GCM-Eth-SL V01.02.XX
    - ".projectarchive" für GCM-P V01.02.XX
V01.02.00 zip 2 MB Download
ZIP-Datei Default-APPs 4888.53.003 V01.xx
  • ZIP-Datei mit Default-App und GCM-P App für dfG-P bis V01.XX.XX mit 144 IOs
    - ".bin.ic" für GCM-Eth-SL V01.02.XX
    - ".projectarchive" für GCM-P V01.02.XX
V01.02.00 zip 2 MB Download
ZIP-Datei Default-APPs 4888.53.004 V01.xx
  • ZIP-Datei mit Default-App und GCM-P App für dfG-P bis V01.XX.XX mit 192 IOs
    - ".bin.ic" für GCM-Eth-SL V01.02.XX
    - ".projectarchive" für GCM-P V01.02.XX
V01.02.00 zip 2 MB Download
Bootloader Tool dfX
  • Bootloader Tool for digsy fusion family
V05.01.00 zip 8 MB Download

Drawings

Download file Version Extension Size
Drawings
pdf 3 KB Download
Module cable dfX
  • Module cable for digsyfusion family
V1.0.0 pdf 27 KB Download

History

Download file Version Extension Size
Modification list

History of modification of DfG-P

V01.04.06 pdf 192 KB Download
© iStock

Create your account

We provide a comprehensive download area for our customers. You do not have an account yet?

Create account

Product inquiry Off-Highway Electronics

Request a call back from our team. Just send us your details using our quick-fill form below we will get in toch very soon: