digsy fusion S-P
Safe Performance
Inter Control completes its successful safety controller series digsy® fusion with the digsy® fusion S-P – targeting on highest demand safety applications. With its powerful CPU & FPU it outperforms existing automation solutions and enables designers to realize extraordinary functionality.
Vast memories allow the storage of detailed logging data over a long period as well as extensive configuration data like load charts for entire machine series.
Due its connectivity featuring 8 CAN busses, 2 Ethernet connectors, USB and RS232 it is able to gather all common machine data, store them and transmit them whenever needed. Common protocols from CANopen / CANopen-Safety up to Ethernet based OPC UA, FTP, UDP and TCP/IP are supported. Easy access via Webserver is available
Performance: ✔ 400 MHz ✔ 4 GB File system ✔ 15 MB Application memory ✔ 48 – 192 Multifunctional IOs
Communication: ✔ 2x Ethernet with switch ✔ OPC UA, FTP, TCP/IP, UDP ✔ 8x CAN ✔ CANopen, CANopen Safety, J1939 ✔ 1x USB ✔ 2x RS232 ✔ Webserver
For further information please click here!
| Safety: ✔ PL d Cat. 2 & 3 according to EN ISO 13849 ✔ AgPL d according to ISO 25119 | EN 16590 PLd ✔ Interference free separation of safe and standard
|