digsy fusion S-P

Safe Performance

Inter Control completes its successful safety controller series digsy® fusion with the digsy® fusion S-P – targeting on highest demand safety applications. With its powerful CPU & FPU it outperforms existing automation solutions and enables designers to realize extraordinary functionality. 

Vast memories allow the storage of detailed logging data over a long period as well as extensive configuration data like load charts for entire machine series.   

Due its connectivity featuring 8 CAN busses, 2 Ethernet connectors, USB and RS232 it is able to gather all common machine data, store them and transmit them whenever needed. Common protocols from CANopen / CANopen-Safety up to Ethernet based OPC UA, FTP, UDP and TCP/IP are supported. Easy access via Webserver is available  

 

Performance: 

400 MHz 

4 GB File system 

15 MB Application memory 

48 – 192 Multifunctional IOs 

 

Communication: 

2x Ethernet with switch

OPC UA, FTP, TCP/IP, UDP 

8x CAN

CANopen, CANopen Safety, J1939 

1x USB 

2x RS232 

Webserver 

 

For further information please click here!

  

 

 

 

 

 

 

 

Safety: 

PL d Cat. 2 & 3 according to EN ISO 13849 

AgPL d according to ISO 25119 | EN 16590 PLd  

Interference free separation of safe and standard
    functions

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 