Article Number: 155131

Minimelt II

Thermal Link

Tmax 206°C / 229°C / 260°C / 298°C / 318°C / Imax15A / slim design / very short reaction time / orientation independent mounting / temperature resistant ceramic housing / standard terminals

Properly installed, the thermal link type 155 131 may be used for applications where a maximum temperature must not be exceeded, for example in coffee makers, irons, dishwashers, dryers and to protect electric  heating elements.

The thermal link has a melt solder insert in the mounting plate which is in direct thermal contact with the surface that is to be monitored. When the preset temperature is reached, the solder melts causing a pin to  move which results in the electrical contacts opening. Resetting is not possible.  

Mounting requirements
During installation, compliance with all relevant electrical requirements must be ensured with  special regard to insulation resistance, dielectric strength, creepage distances and clearances both under normal  conditions and in case of a fault, as specified in the relevant equipment standard, for example DIN VDE 0700 (IEC 60335-1).
The requirements in the application note in appendix A of the DIN VDE 0821 EN 60 691 shall be taken into consideration. When mounting the thermal link the following requirements shall be observed:
- the terminals shall be used for internal connections only;
- the switch mechanism inside the ceramic housing must not be touched by any tools or similar objects to avoid damage and possible malfunctions.

Advantages Technical data Applications Downloads Callback
Minimelt II

The advantages of Minimelt II

  • easy mounting

    quick + safe + economically

  • high current carrying capacity up to 15 A

    switches off even under larger loads

  • very quick response time

    ideally suited for powerful heating elements

  • long continuous operation and high limit temperature

    more security for your application

  • slim design

    when design could be an obstacle

  • high product quality

    reliable through automated production

Details

fixed Thermal Link


The thermal link „Minimelt II“ is approved according to DIN EN 60 691 and is suitable for the following conditions: 

Ambient conditions: The thermal link is intended for use in normal atmospheric conditions.
Circuit conditions: The thermal link is intended for use in resistive circuits only.
Proof tracking index: PTI > 250

Characteristic Currents

VDE

*) cURus

Rated current  Ir  15 A
Interrupting current  Ib  22,5 A
Transient overload current  Ip  225 A
Rated Voltage Ur  230 V
    *) cURus = UL / CSA

Note concerning type number
The complete number will be issued by the manufacturer together with a drawing based on the specific design.

Type designation code: e.g.

155131. 301 01 7 B
1 2 3 4 5

1 Type (identifies design)
2 Variants suffix (identifies dimensions, terminals, fixing arrangements)
3 Date of production – week
4 Date of production – year
5 Code for manufacturing plant

 

Special instructions
The thermal link should neither be coated or potted nor be used in impregnated windings.
The thermal link is a non repairable part. In case of replacement an equivalent thermal
link with the same type number and rated functional temperature Tf should be used,
mounted in exactly the same way. Th  does not relate to the ambient temperature
only but to the temperature measured at the mounting plate close to the thermal element.
According to UL/EN 60 691/10.6 in the case of a fault, a rate of temperature change of
> 1K per minute is required between Th  and Tf +5K to trip the thermal link.

 

Characteristic Temperature
Tf ... Rated functioning temperature
Th ... Holding temperature according to DIN EN 60691 (measured at mounting plate close to the thermal element)
Tm ... Maximum temperature limit

Tf-10 K

Th

Tm

206°C 170°C 500°C
229°C 205°C 500°C
260°C 230°C 500°C
298°C 260°C 500°C
318°C 280°C 500°C

Tolerance for Tf  acc. to VDE 0821 / EN 60 691 - 10 °C

Properly installed, the thermal link type 155 131 may be used for applications where a maximum temperature must not be exceeded, for example in coffee makers, irons, dishwashers, dryers and to protect electric  heating elements.

 

The thermal link has a melt solder insert in the mounting plate which is in direct thermal contact with the surface that is to be monitored. When the preset temperature is reached, the solder melts causing a pin to  move which results in the electrical contacts opening. Resetting is not possible.  

Mounting requirements
During installation, compliance with all relevant electrical requirements must be ensured with  special regard to insulation resistance, dielectric strength, creepage distances and clearances both under normal  conditions and in case of a fault, as specified in the relevant equipment standard, for example DIN VDE 0700 (IEC 60335-1).
The requirements in the application note in appendix A of the DIN VDE 0821 EN 60 691 shall be taken into consideration. When mounting the thermal link the following requirements shall be observed:
- the terminals shall be used for internal connections only;
- the switch mechanism inside the ceramic housing must not be touched by any tools or similar objects to avoid damage and possible malfunctions.

  • current supply up to 15 A
  • protected contact system, no cover cap required
  • very fast response time thanks to integrated solder strut in the base plate
  • constant response time for different installation positions
  • easy mounting
  • high continuous operating temperature Th
  • high quality through fully automated production

The Approbation List will be provided upon request.

Applications

  • Major Appliances © AdobeStock

    Major Appliances

    Dishwasher, oven, professional cooking systems, washer

  • Small household appliances © AdobeStock

    Small household appliances

    Multifunction stove, deep fryer, waffle maker, steamer, rice stove

  • Beverage processing © AdobeStock

    Beverage processing

    Fully automatic coffee machines, milk frothers, tea machines, samovars

  • Clothing preparation / steam cleaning © iStock

    Clothing preparation / steam cleaning

    Iron, steam station, steam straightener, steam cleaner

  • Building heating / space heating © AdobeStock

    Building heating / space heating

    Heat pump, night storage heater, oil radiator, fan heater, frost monitor

  • Industrial applications © iStock

    Industrial applications

    Switch cabinet heating, switch cabinet cooling, industrial heating

  • Further application © iStock

    Further application

    Thick film heater, vaporizer, sterilizer, baby bottle warmer, hot glue gun, laminator

Downloads

List of all available downloads.

Download file Version Extension Size
Data sheet_155131
pdf 489 KB Download

Product inquiry Controls